SLE 5000 w/o HFO artificial lung ventilation apparatus for newborns
Function
The SLE 5000 artificial lung ventilation apparatus is a complete or partial prosthetics of respiratory function in a patient with respiratory failure, while the device injects the respiratory mixture into the respiratory tract through the intubation tube.
Advantages
Ventilation Modes
Specifications
Traditional ventilation modes CPAP / PTV / PSV | |
Inhalation time | 0.1 - 3.0 sec. |
CPAP pressure | 0 - 20 mbar |
Inhalation pressure | 0 - 65 mbar |
Specified volume | 2 - 200 ml |
FiO2 | 21% - 100% |
CMV / SIMV | |
BPM (breathing rhythm) | 1-150 inhalation/min. |
Inhalation/expiration rate (I:E) | 11.2:1 - 1:600 |
Inhalation time | 0.1 - 3.0 sec. |
PEEP pressure | 0 - 20 mbar |
Inhalation pressure | 0 - 65 mbar |
Specified volume | 2 - 200 ml |
FiO2 | 21% - 100% |
Monitoring Parameters of Flow and Volume Measurement | |
Flow sensor type - double heated anemometer (autoclavable or disposable) | 10 mm |
Flow (Accuracy±8%) | 0.2 - 32 l / min |
Expiratory tidal volume | 0 - 999 ml |
Expiratory minute volume | 0 - 18 l |
Dead spot | 1 ml |
Weight | 10 g |
Traditional Ventilation and Combined Modes: | |
Leakage in a patient | 0 - 50% (Resolution - 5%, average for the last 5 breaths) |
Total breathing rate | 0 - 150 inhalation/min. |
Dynamic compliance | 0 - 100 ml/mbar (Resolution - 1 ml/mbar) |
C20/C | resolution 0.1 |
Measurement time | 2 msec |
Resistance | 0-1000 mbar.sec / l |
Flow trigger sensitivity | 0.2 - 10 l / min |
Oxygen concentration
Range | 21 - 100% (resolution 1%) |
Pressure
Pressure measurement in real time | Resolution 1 mbar |
Measurement time | 2 msec |
Peak pressure | 0 - 175 mbar (Resolution - 1 mbar) |
PEEP pressure | 0 - 175 mbar (Resolution - 1 mbar) |
Mean pressure | -175 - 175 mbar (Resolution - 1 mbar) |
User-Defined Alarms
Peak pressure Auto install, when the patient pressure control is adjustable or can be adjusted manually | |
Range | 10 - 110 mbar |
Resolution | 0.5 mbar |
Cycle Failure Auto install, when the patient pressure control is adjustable or can be adjusted manually | |
Low pressure Auto install, when the patient pressure control is adjustable or can be adjusted manually | |
Range | 10 - 70 mbar |
Traditional modes, HFO modes | up to 10 mbar below the high pressure threshold |
Low Tidal Volume | |
Range | 0 - 200 ml |
Resolution | 0.2 ml |
Low Minute Volume | |
Range | from 0 to 0.02 liters below the High Minute Volume Threshold |
Resolution | 0.2 ml |
High Minute Volume | |
Range | 0.02 from 18 l |
Resolution | 0.1 l |
Apnea Time Set in CPAP or when the respiratory support rate is less than 20 BPM Range | from 3 to 60 sec |
Resolution | 1 sec |
Power
Voltage | 100-250 V / 50-60 Hz |
Power | 115 VA |
Battery | 45-60 minutes |
Battery charge | Full charge for 24 hours, 80% charge - for 8 hours |
Outputs - RS-232C
Air and O2 connection
Pressure | 3 - 5 bar |
Fresh gas flow | 8 l/min |
Maximum gas flow | 60 l/min |
Application environment
Temperature of | 10 - 40 ºC |
Humidity | 0-90% (without condensation) |
Dimensions
Size, fan only | 330mm (L) x 330mm (H) x 470mm (D) |
Height on a short rack | 114 cm |
Height on a high rack | 131 cm |
Weight, fan without rack | 21.8 kg |